Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
install:upgrading:home [2011/04/05 20:21]
admin
install:upgrading:home [2012/10/26 14:51] (current)
Line 1: Line 1:
 {{page>:​top_add&​nofooter&​noeditbtn}} {{page>:​top_add&​nofooter&​noeditbtn}}
  
-====== Upgrading from previous versions ​======+====== ​Omnidex ​Upgrading from Previous Releases ​======
  
-===== Upgrading ​from Version 5.1 to 5.2 ===== +===== Reasons to Upgrade ​from 4.x to 5.x =====
-Although 5.2 has not yet been released, there are a few items that are known changes from 5.1 to 5.2 that are worth knowing during 5.2 development.+
  
-The following is a list of items these known changes.+There are several good reasons to upgrade from an Omnidex version 4.x installation to a 5.x installation.
  
-=== Connection strings have changed === +  * Faster Omnidex Index build times due to the merging of MDK and ASK indexes. 
-=== C STRING data type is now STRING ===+  * Easier to maintain Omnidex Grid Environments with Grid aware Explain Plans 
 +  * Easier Omnidex Environment setup and maintenance using the Omnidex Data Defintion Language and OdxSQL. 
 +  * Improvements in the Sample and Random selection of records. 
 +  * Automatically de-dup records on selection. 
 +  * Cached Qualifications to improved the speed of drill down counts. 
 +  * PowerSearch for synonyms, miss-spellings,​ transpositions,​ plurality, etc. 
 +  * Autocomplete suggestions of words as they are being typed.
  
-The C STRING data type has been renamed ​to STRING in 5.2.  ​C STRING ​is still supported ​as a synonym ​and will continue to work in the legacy Environment Catalogs as well as in the new Omnidex ​Data Definition Language (DDL) syntax.  ​However,​ it may be removed in future versions so all new Omnidex Environments should use the STRING syntax when referring to Character columns that can be NULL terminated for faster internal Omnidex processing. +===== Reasons ​to stay on 4.x ===== 
 +  * NsAdmin ​is no longer ​supported and the replacement interface is not available ​in the Omnidex ​5.1 version.
  
-=== RegMaint and SysInfo functionality included in OdxSQL ​===+===== Upgrading from previous Omnidex versions =====
  
-As part of DISC's continuing efforts ​to simplify ​the Omnidex product, the licensing functionality in the sysinfo and regmaint programs has been moved to the OdxSQL program.+The best way to currently review all the upgrade notes is to start at the older releases and read through to the newer releases. ​ Even if you are already on 5.0, you should review ​the upgrade notes on going from 4.x to 5.0 to see all the changes ​to the Omnidex product.
  
-=== TDF is now ... === 
-=== Omnidex ODBC driver name change === 
  
-The Omnidex ODBC driver has been renamed as of the 5.2 release which can impact existing Microsoft Machine DataSources which are referred ​to as System and User data sources in the Data Sources Administrator.+[[install:​upgrading:​v4x_to_v50 | Upgrading Versions 4.x to 5.0 ]]
  
-The existing name is Omnidex ODBC Driver for OdxNet.+[[install:​upgrading:​50_to_v51 | Upgrading Versions 5.0 to 5.1 ]]
  
-The new name is Omnidex ODBC Driver. 
  
-DISC provides a program called odbcreg that can register the Omnidex ODBC driver under the supported Windows Operating Systems.  ​ 
  
-As of 5.2, this program has the option ​to register the old name as well as the new ODBC Driver name so that each datasource does not have to be converted.+==== Correct Steps to convert existing oacomp Environment ​to DDL based XML Environment ==== 
 +  * Modify 4.x environment source to test environment locations (table physical, database index_prefix,​ etc.)
  
 +  * Compile environment source using oacomp 5.1
  
-===== Upgrading from Versions 5.0 to 5.1 =====+  * Run dbinstal install only (no build) script
  
-=== Connection strings supported but changing in 5.2 ===+  * Run OdxSQL and do the following steps (assume current.env)
  
-===== Upgrading from Versions 4.x to 5.0 =====+  * Use Odxsql connect ​to .env environment
  
-=== OdxAdmin'​s release has been delayed === +  os> odxsql current.env
-DISC is developing a Windows based front end to administer Omnidex in a multi-server environment. ​ However, due to other customer driven priorities, the Omnidex Administrator is not available in either 5.0.+
  
-OdxAdmin ​will incorporate ​the NsAdmin ​and DsEdit functionality once it is released. +  * Use OdxSQL to extract the new DDL from the current.env. ​ This will include both the metadata from the Environment Catalog ​and the Omnidex indexing information.
  
-=== NsAdmin no longer supported ===+  odxsql> extract DDL to myddl.sql ​
  
-=== DsEdit no longer supported ===+  * Compile the extracted DDL to create a new Omnidex Environment with the XML format. 
 +  
 +  odxsql> use myddl.sql ​
  
-=== Oracle and SQLServer Stored Procedure interfaces no longer documented ===+  * Connect to XML environment
  
-=== Switching between two versions ===+  odxsql> connect myddl.xml
  
-PATH +  * Build the new indexes
-CLASSPATH +
-OMNIDEX_HOME+
  
-cmd> odbcreg -i "​program files\omnidex 5.1\bin"​+  odxsql> update indexes 
 + 
  
-cmd> odbcreg -i "​program files\omnidex 4.4\bin"​ 
  
  
-=====  ===== 
  
-**[[prev|Prev]]** | **[[next|Next]]** 
  
 ====== Additional Resources ====== ====== Additional Resources ======
 
Back to top
install/upgrading/home.1302034863.txt.gz · Last modified: 2012/10/26 14:48 (external edit)